Real Time

1. System Requirements

Installation Steps: 1 2 3 4 5 6 7

To generate signals using the N7649B Test Case Manager software, you must have properly configured software, instrument, and PC, as described in the following tables.

Test Case Manager Software Option Requirement

Model-Option

Description

N7649B-ETP

LTE FDD and TDD eNB receiver tests

N7649B-FTP

W-CDMA / HSPA+ BTS receiver tests

Signal Studio Software Option Requirements

Depending on the mobile standard you are testing, the following software options are required to generate and play back wanted and interferer signals.

For LTE FDD Tests

To understand what option is required for a test, see Option License Matrices.

Clause 6, Test Case 6.2.6—Requires a W-CDMA UTRA Interferer

Model-Option

Description

N7600B-EFP

Basic W-CDMA / HSPA R7

N7600B-3FP

Connect to N5182A/B MXG or N5172B EXG signal generator

All other LTE FDD Tests

Model-Option

Description

N7624B

Signal Studio for LTE/LTE-Advanced FDD version 14.0 or later

N7624B-HFP1

Basic LTE FDD

N7624B-JFP1

Basic LTE-Advanced FDD

N7624B-SFP1

Advanced LTE FDD

N7624B-TFP1

Advanced LTE-Advanced FDD

N7624B-WFP2

Advanced LTE FDD real-time UL R9

N7624B-1FP3

Connect to E4438C ESG signal generator

N7624B-3FP3

Connect to N5182A/B MXG or N5172B EXG signal generator

N7624B-6FP3

Connect to N5106A Baseband Generator and Channel Simulator

1. With some exceptions, Option WFP can be used in lieu of this option to perform tests that use waveform files, but this option is required to use the file created with the Export Signal Studio Setting... function.

2.Required for Clause 8 tests that use a real-time signal and can be used for tests that require Options HFP and SFP.

3. Only one connectivity option is required. Select the option that matches your instrument.

For LTE TDD Tests

To understand what option is required for a test, see Option License Matrices.

Clause 6, 6.2.6—Requires a W-CDMA UTRA Interferer

Model-Option

Description

N7600B-EFP

Basic W-CDMA / HSPA R7

N7600B-3FP

Connect to N5182A/B MXG or N5172B EXG signal generator

All other LTE TDD Tests

Model-Option

Description

N7625B

Signal Studio for LTE/LTE-Advanced TDD version 14.0 or later

N7625B-EFP1

Basic LTE TDD

N7624B-JFP1

Basic LTE-Advanced TDD

N7625B-QFP1

Advanced LTE TDD

N7624B-TFP1

Advanced LTE-Advanced TDD

N7625B-WFP2

Advanced LTE TDD real-time UL R9

N7625B-1FP3

Connect to E4438C ESG signal generator

N7625B-3FP3

Connect to N5182A/B MXG or N5172B EXG signal generator

N7625B-6FP3

Connect to N5106A Baseband Generator and Channel Simulator

1.With some exceptions, Option WFP can be used in lieu of this option to perform tests that use waveform files, but this option is required to use the file created with the Export Signal Studio Setting...

2.Required for Clause 8 tests that use a real-time signal and can be used for tests that require Options EFP and QFP.

3. Only one connectivity option is required. Select the option that matches your instrument

For W-CDMA Tests

To understand what option is required for a test, see Option License Matrices.

Model-Option

Description

N7600B

Signal Studio for W-CDMA / HSPA+ version 12.21 or later

N7600B-EFP

Basic W-CDMA / HSPA R7

N7600B-FFP

Basic W-CDMA / HSPA+ R8

N7600B-QFP

Advanced W-CDMA / HSPA+ R11

N7600B-WFP2

Advanced W-CDMA/HSPA+ Real-time R8 UL

N7600B-1FP3

Connect to E4438C ESG signal generator

N7600B-3FP3

Connect to N5182A/B MXG or N5172B EXG signal generator

N7600B-6FP3

Connect to N5106A Baseband Generator and Channel Simulator

1. This version is required to use the exported Test Case Manager test settings.

2. Required for tests that use a real-time signal and can be used for tests that require Options EFP, FFP, and QFP.

3. Only one connectivity option is required. Select the option that matches your instrument

Supported Instruments and Recommended Options

Recommended options are denoted by parenthesis ().

For LTE FDD and TDD Tests

As indicated in the table, some instruments are only applicable to certain test clauses and for some, only certain application for that clause. Ensure that the correct instrument model is selected for the application.

Model-Option

Description

Clause 6 Interferer

N5182B-506, 656, 1EQ, 403, UNV, UNY

MXG X-Series vector signal generator

Firmware version B.01.51 or later (how to upgrade)

N5172B-506, 653, 403, UNV

EXG X-Series vector signal generator

Firmware version B.01.51 or later (how to upgrade)

N5182A-506, 652, 403, 1EQ, UNV

First generation MXG vector signal generator

Firmware version B.01.20 or later (how to upgrade)

Clause 7 Wanted, E-UTRA interferer, CW interferer

N5182A-506, 652 or (6541), 403, 1EQ, UNV

First generation MXG vector signal generator

Firmware version B.01.20 or later (how to upgrade)

E4438C-506, 601 or (6021), 403

E4438C ESG signal vector generator

Firmware version C.05.84 or later (how to upgrade)

Clause 7 CW interferer for blocking test

N5183A-520

MXG microwave analog signal generator

Firmware version A.01.86 or later (how to upgrade)

E8257D-520, UNX

PSG analog signal generator

Firmware version C.06.21 or later (how to upgrade)

Clause 7 and 8 including MIMO and Channel Fading—Wanted, E-UTRA interferer, CW interferer

N5106A-622, 632 or 6342, EFP, JFP, QFP, TFP

PXB Baseband Generator and Channel Emulator

Firmware versions 2.2.0 or later (how to upgrade)

N5182B-5063,4,5, 656 or (6571), 6606, 1EQ, 403, UNV, UNY

MXG X-Series vector signal generator

Firmware version B.01.51 or later (how to upgrade)

N5172B-5063,4,5, 653 or (6551), 6606, 403, UNV

EXG X-Series vector signal generator

Firmware version B.01.51 or later (how to upgrade)

1. For Clause 7 tests, wider baseband bandwidth option is recommended for single signal generator operation that combines wanted and interferer as delta frequency is limited by baseband bandwidth.

2.The Option 632 is for 2x Rx Antenna and Option 634 is for 4x Rx Antenna.

3. This is the only option required when using this signal generator as an RF upconvertor for the N5106A.

4. When using with the N5106A for MIMO tests, the number of signal generators used needs to match the number of Rx antennas on the eNB.

5. All instrument options required when using with an external fader.

6. This option required for only one signal generator when all of the following conditions are true:

For W-CDMA Tests

Model-Option

Description

Clause 6 Interferer

 

N5182B-506, 656, 1EQ, 403, UNV5

MXG X-Series vector signal generator

Firmware version B.01.20 or later (how to upgrade)

N5172B-506, 653, 403, UNV5

EXG X-Series vector signal generator

Firmware version B.01.20 or later (how to upgrade)

N5182A-506, 652, 403, 1EQ, UNV5

First generation MXG vector signal generator

Firmware version B.01.20 or later (how to upgrade)

Clause 7 and 8 Wanted, W-CDMA/GMSK/CW1 interferer

N5106A2-614, EFP, JFP, QFP

PXB Baseband Generator and Channel Emulator

Firmware versions 2.2.0 or later (how to upgrade)

N5182B-5063, 656 or (657), 6604, 1EQ, 403, UNV, UNY

MXG X-Series vector signal generator

Firmware version B.01.20 or later (how to upgrade)

N5172B-5063, 653 or (655), 6604, 403, UNV

EXG X-Series vector signal generator

Firmware version B.01.20 or later (how to upgrade)

N5182A-506, 652 or (654), 403, 1EQ, UNV5, (019)

First generation MXG vector signal generator

Firmware version B.01.20 or later (how to upgrade)

E4438C-506, 601 or (602), 403

E4438C ESG signal vector generator

Firmware version C.05.84 or later (how to upgrade)

Clause 7 CW interferer for blocking test

N5183A-520

MXG microwave analog signal generator

Firmware version A.01.86 or later (how to upgrade)

E8257D-520, UNX

PSG analog signal generator

Firmware version C.06.21 or later (how to upgrade)

1. CW interferer at frequencies <=6 GHz

2. The N5106A PXB pairs with only the N5182B or the N5172B X-Series RF Vector Signal Generators.

3. If paired with an N5106A PXB, the signal generator requires only Option 506.

4. Real-time option required for Clause 8 tests when using an external fader.

5. Option UNV Enhanced Dynamic Range is needed when using a high-power interferer that is close to the wanted signal.

PC Requirements

200 GB HDD with 2 GB free disk space at runtime (5 GB or higher recommended)

1024 x 768 screen resolution (1280 x 1024 recommended)

Windows® 7 Professional/Ultimate/Enterprise, 32-bit and 64-bit versions

Windows XP Professional, SP3 32-bit

Microsoft Windows Installer, version 3.1 or later

Keysight License Manager, version 3.7 or later

Keysight IO Libraries, version 15.5 or later

Microsoft .NET Framework 4.6