SIB19 Information

SIB19 Information

Last updated: October 19, 2012

This section is only application to the lab application.

As specified in the 3GPP standard, the system information block type 19 contains Inter-RAT frequency and priority information to be used in the cell. The test set support SIB 19 by the following parameters:

SIB19 Info

This setting determines whether or not SIB19 shall be transmitted via the BCCH.

GPIB command: CALL[:CELL]:BCCHannel:SIB19[:INFormation]

SIB 19 UTRA Info List

SIB19 E-UTRA Info List

The SIB19 E-UTRA Info List provides eight different E-UTRA Frequency and Priority Information entries, indexing from 1 to 8. Each entry allows you to configure the following fields: Measurement Bandwidth, priority, QrxlevminEUTRA, Threshx, high, Threshx, low and E-UTRA detection.